cryogenic liquid storage tankswere shipped by TAIDA GLOBAL on June 18, 2026, to Balikpapan, East Kalimantan, Indonesia, for an industrial gas storage and distribution project.
The vertical configuration was selected to reduce the required installation footprint while providing centralized storage for low-temperature industrial liquids. Before shipment, the tank bodies, piping connections, valves, safety devices, vacuum insulation systems, lifting points, surface finish, and transport supports were inspected.
Due to the dimensions and center of gravity of the equipment, the loading plan included dedicated support structures, protection for exposed valves and pipelines, and reinforced securing arrangements. The tanks were then prepared for inland transportation and sea shipment to Indonesia.
The main specifications are as follows:
Vertical cryogenic liquid storage tank:
Tank capacity range: 5–250 m³
Configuration: Vertical
Applicable media: LNG, LO₂, LN₂, LAr, LCO₂
Working pressure: 0.8–2.1 MPa
Minimum design metal temperature: -196°C / -40°C
Insulation type: Vacuum powder insulation / high-vacuum multilayer insulation
Main materials: S30408 / 16MnDR / Q345R
Non-destructive testing ratio: 100%
Strength after strain strengthening: ≥737 MPa
Fatigue resistance: ≥50,000 cycles
Vacuum interlayer leakage rate: ≤1 × 10⁻⁸ Pa·m³/s
Sealed vacuum level: ≤0.1 Pa
Vacuum interlayer service life: ≥5 years
Installation arrangement: Customized according to the project layout and operating requirements
The storage tank capacity, working pressure, piping arrangement, valve configuration, and installation layout can be adjusted according to the stored medium, site conditions, operating requirements, and applicable project specifications.
TAIDA GLOBAL supports Indonesian customers with technical selection, specification confirmation, production coordination, quality inspection, export packaging, loading, and delivery planning.